Preparing The Configuration - Innominate mGuard Reference Manual

Table of Contents

Advertisement

mGuard centerport
204
Innominate Security Technologies
11.4

Preparing the configuration

11.4.1
Connection requirements
For mGuard centerport, the two power supply units must be connected to the power
supply source/to the mains. (If only one power supply unit is connected, the device can
actually be operated, but it will output an acoustic signal.)
For local configuration: The computer that is to be used for configuration must be
connected to the LAN socket on the mGuard.
For remote configuration: The mGuard must be configured so that remote configura-
tion is permitted.
The mGuard must be connected, i.e., the required connections must be working.
11.4.2
Local configuration on startup (EIS)
As of firmware version 7.2, initial startup of mGuard products provided in Stealth mode is
considerably easier. From this version onwards, the EIS (Easy Initial Setup) procedure en-
ables startup to be performed via preset or user-defined management addresses without
actually having to connect to an external network.
The mGuard is configured using a web browser on the computer used for configuration.
NOTE: The web browser used must support SSL encryption (i.e., HTTPS).
According to the default setting, the mGuard can be accessed via the following addresses:
Table 11-3
Preset addresses
Default setting
mGuard centerport
Network
Management IP #1
mode
Router
Management IP #2
https://192.168.1.1/
I15007_en_02

Advertisement

Table of Contents
loading

Table of Contents