mGuard smart²/smart
Reset button
(Located in the opening.
Can be pressed with a
straightened paper clip,
for example.)
Table 6-2
LEDs on the mGuard smart²
LED
State
1
Green
On
Flashing
2
Red/gree
Flashing
n
Green
Flashing
Red
Flashing
3
Green
On
Flashing
1, 2, 3
Various LED light
codes
110
Innominate Security Technologies
6.1
Operating elements and LEDs
Figure 6-2
Operating elements and LEDs on the mGuard smart²
Meaning
LAN: connection to the network partner is present
LAN: data transmission is active
Boot process. When the device has just been connected to the power supply. After a
few seconds, this LED changes to the heartbeat state.
Heartbeat. The device is correctly connected and operating.
System error. Restart the device.
•
Press the Reset button (for 1.5 seconds).
•
Alternatively, briefly disconnect the device power supply and then connect it again.
If the error is still present, start the recovery procedure (see "Performing a recovery pro-
cedure" on page 121) or contact your dealer.
WAN: connection to the network partner is present
WAN: data transmission is active
Recovery mode. After pressing the Reset button.
See "Restart, recovery procedure, and flashing the firmware" on page 120.
LED 1
LED 2
LED 3