6.4

Preparing the configuration

6.4.1
Connection requirements
The mGuard smart² must be switched on, i.e., it must be connected to a computer (or
power supply unit) that is switched on via a USB cable in order for it to be supplied with
power.
For local configuration: The computer used for configuration:
Must be connected to the LAN port of the mGuard
Or must be connected to the mGuard via the local network
For remote configuration: The mGuard must be configured so that remote configura-
tion is permitted.
The mGuard must be connected, i.e., the required connections must be working.
6.4.2
Local configuration on startup (EIS)
As of firmware version 7.2, initial startup of mGuard products provided in Stealth mode is
considerably easier. From this version onwards, the EIS (Easy Initial Setup) procedure en-
ables startup to be performed via preset or user-defined management addresses without
actually having to connect to an external network.
The mGuard is configured using a web browser on the computer used for configuration.
NOTE: The web browser used must support SSL encryption (i.e., HTTPS).
According to the default setting, the mGuard can be accessed via the following addresses:
Table 6-3
Preset addresses
Default setting
mGuard smart²
The mGuard is preset to the "multiple Clients" stealth configuration. You need to configure
a management IP address and default gateway if you want to use VPN connections (see
Page 117). Alternatively, you can select a different stealth configuration or use another net-
work mode.
Network
Management IP #1
mode
Stealth
https://1.1.1.1/
mGuard smart²/smart
Management IP #2
https://192.168.1.1/
Innominate Security Technologies