Mounting
Removal
I15007_en_02
3.3
Installation of mGuard rs4000/rs2000 3G
3.3.1
Mounting/removal
NOTE: Device damage
Only mount and remove devices when the power supply is disconnected.
The device is ready to operate when it is supplied. The recommended sequence for mount-
ing and connection is as follows:
•
Mount the mGuard rs4000/rs2000 3G on a grounded 35 mm DIN rail according to
DIN EN 60715.
Figure 3-3
Mounting the mGuard rs4000/rs2000 3G on a DIN rail
•
Attach the top snap-on foot of the mGuard rs4000/rs2000 3G to the DIN rail and then
press the mGuard rs4000/rs2000 3G down towards the DIN rail until it engages with a
click.
•
Remove or disconnect the connections.
•
To remove the mGuard rs4000/rs2000 3G from the DIN rail, insert a screwdriver hori-
zontally in the locking slide under the housing, pull it down – without tilting the screw-
driver – and then pull up the mGuard rs4000/rs2000 3G.
mGuard rs4000/rs2000 3G
Innominate Security Technologies
55