Action
I15007_en_02
12.8.2
Performing a recovery procedure
The network configuration (but not the rest of the configuration) is to be reset to the delivery
state, as it is no longer possible to access the mGuard.
When performing the recovery procedure, the default settings are established:
Table 12-6
Preset addresses
Default setting
mGuard industrial rs
The mGuard is reset to Stealth mode with the default setting "multiple Clients".
The CIFS integrity monitoring function is also disabled because this only works when
the management IP is active.
In addition, MAU management is switched on for Ethernet connections. HTTPS access
is enabled via the local Ethernet connection (LAN).
The settings configured for VPN connections and the firewall are retained, including
passwords.
Possible reasons for performing the recovery procedure:
The mGuard is in Router or PPPoE mode.
The configured device address of the mGuard differs from the default setting.
The current IP address of the device is not known.
Up-to-date information on the recovery and flashing procedure can be found in the appli-
cation note for your mGuard firmware version.
You can find application notes under the following Internet address:
www.innominate.com.
Slowly press the Reset button six times.
After approximately 2 seconds, the State LED lights up green.
Press the Reset button slowly again six times.
If successful, the State LED lights up green.
If unsuccessful, the Error LED lights up red.
If successful, the device restarts after two seconds and switches to Stealth mode. The de-
vice can then be reached again under the corresponding addresses.
Network
Management IP #1
mode
Stealth
https://1.1.1.1/
mGuard industrial rs
Management IP #2
https://192.168.1.1/
Innominate Security Technologies