Connecting The Mguard Delta² - Innominate mGuard Reference Manual

Table of Contents

Advertisement

mGuard delta²
78
Innominate Security Technologies
4.3
Connecting the mGuard delta²
NOTE: Notes on mounting and installation
Only connect the RJ45 Ethernet ports of the mGuard to matching network installations.
Some telecommunications connections also use RJ45 sockets. You may not connect
these to the RJ45 ports of the mGuard.
Safe isolation of live circuits is only guaranteed if connected devices fulfill requirements
specified by VDE 0106-101 (safe isolation). The supply lines must be isolated or laid sep-
arately to live circuits.
4.3.1
Connecting to the network
Connect the mGuard to the network. To do this, you need a suitable UTP cable (CAT5)
which is not included in the scope of supply.
Connect the internal network interface LAN 1 of the mGuard to the corresponding
Ethernet network card of the configuration computer or a valid network connection of
the internal network (LAN).
4.3.2
Connecting the supply voltage
Connect the wide-range power supply unit of the mGuard to a suitable power supply.
Connect the low-voltage plug of the power supply unit on the back of the mGuard.
Figure 4-3
Low-voltage plug of the power supply unit
The status LED PWR lights up green when the supply voltage has been connected properly.
The mGuard boots the firmware. Status LED STAT flashes green.
The mGuard is ready for operation as soon as the LAN/WAN LEDs of the Ethernet socket
light up.
Additionally, the status LED PWR lights up green and the status LED STAT flashes green
at heartbeat.
I15007_en_02