mGuard industrial rs
Mounting
Removal
218
Innominate Security Technologies
12.3
Installation of mGuard industrial rs
WARNING: The housing must not be opened.
WARNING: The shielding of the connected twisted pair cables is electrically connected
to the front plate.
WARNING: This is a Class A item of equipment. This equipment can cause radio interfer-
ence in residential areas; in this case, the operator may be required to implement appro-
priate measures. When installed in residential or office areas, the mGuard industrial rs
may only be operated in control cabinets with fire protection properties according to
EN 60950-1.
12.3.1
Mounting/removal
The device is ready to operate when it is supplied. The recommended sequence for mount-
ing and connection is as follows:
•
Pull out the terminal block from the bottom of the mGuard industrial rs and wire the sig-
nal lines and other connections as required (see "Connection options on the lower ter-
minal block" on page 220).
•
Tighten the screws on the screw terminal blocks with at least 0.22 Nm.
Wait to insert the terminal block base.
•
Mount the mGuard industrial rs on a grounded 35 mm DIN rail according to
DIN EN 60715.
The device conducts the grounding provided by the DIN rail through the left-hand con-
tact (ground connection) of the lower terminal strip.
Figure 12-3
Mounting the mGuard industrial rs on a DIN rail
•
Attach the top snap-on foot of the mGuard industrial rs to the DIN rail and then press
the mGuard industrial rs down towards the DIN rail until it engages with a click.
•
Insert the wired terminal block.
•
Connect the supply voltage at the top of the terminal block (see "Connecting the supply
voltage" on page 219).
•
Make any necessary network connections at the LAN port or WAN port (see "Connect-
ing to the network" on page 219).
•
Connect the corresponding device at the Serial port as required (see "Serial port" on
page 223).
•
Remove or disconnect the connections.
I15007_en_02