Mounting
Removal
I15007_en_02
2.3
Installing the mGuard rs4000/rs2000 Switch
2.3.1
Mounting/removal
NOTE: Device damage
Only mount and remove devices when the power supply is disconnected.
The device is ready to operate when it is supplied. The recommended sequence for mount-
ing and connection is as follows:
•
Mount the mGuard rs4000/rs2000 Switch on a grounded 35 mm DIN rail according to
DIN EN 60715.
Figure 2-3
Mounting the mGuard rs4000/rs2000 Switch on a DIN rail
•
Attach the top snap-on foot of the mGuard rs4000/rs2000 Switch to the DIN rail and
then press the mGuard rs4000/rs2000 Switch down towards the DIN rail until it engag-
es with a click.
•
Remove or disconnect the connections.
•
To remove the mGuard rs4000/rs2000 Switch from the DIN rail, insert a screwdriver
horizontally in the locking slide under the housing, pull it down – without tilting the
screwdriver – and then pull up the mGuard rs4000/rs2000 Switch.