Input/CMD I1, CMD I2
Operating a connected
push button
Operating a connected
on/off switch
Signal contact (signal out-
put) ACK O1, O2
Alarm output ACK O3
I15007_en_02
The switching inputs and switching outputs can be connected with signals from external de-
vices, e.g., with signals from PLCs. In this case, ensure the same potential as well as voltage
and current specifications are defined.
Depending on the firmware version used, the service contacts can be used for various
switching or signaling tasks.
Service contacts as of firmware version 8.1
Via the web interface under "Management, Service I/O", you can set whether a push button
or an on/off switch has been connected to the inputs. One or more freely selectable VPN
connections or firewall rule records can be switched via the corresponding switch. A mixture
of VPN connections and firewall rule records is also possible. The web interface displays
which VPN connections and which firewall rule records are connected to this input.
The push button or on/off switch is used to establish and release predefined VPN connec-
tions or the defined firewall rule records.
To switch on the selected VPN connections or firewall rule records, press and hold the
push button for a few seconds and then release the push button.
To switch off the selected VPN connections or firewall rule records, press and hold the
push button for a few seconds and then release the push button.
To switch on the selected VPN connections or firewall rule records, set the switch to
ON.
To switch off the selected VPN connections or firewall rule records, set the switch to
OFF.
Via the web interface under "Management, Service I/O" you can set whether certain VPN
connections or firewall rule records are monitored and displayed via the LED Info 1 (out-
put/ACK O1) or LED Info 2 (output/ACK O2).
If VPN connections are being monitored, an illuminated Info LED indicates that VPN con-
nections are established.
The O3 alarm output monitors the function of the mGuard rs4000/rs2000 and therefore en-
ables remote diagnostics.
The Fault LED lights up red if the signal output takes low level due to an error (inverted
logic).
The O3 alarm output reports the following when "Management, Service I/O, Alarm output"
has been activated.
Failure of the redundant supply voltage
Monitoring of the link status of the Ethernet connections
Monitoring of the temperature condition
Monitoring of the connection state of the internal modem
mGuard rs4000/rs2000
Innominate Security Technologies
17