I15007_en_02
10.4
Preparing the configuration
10.4.1
Connection requirements
–
The mGuard blade must be mounted in the mGuard bladebase and at least one of the
bladebase device's power supply units must be in operation.
–
For local configuration: The computer used for configuration:
–
Must be connected to the LAN socket of the mGuard
–
Or the computer must be connected to the mGuard via the network.
–
For remote configuration: The mGuard must be configured so that remote configura-
tion is permitted.
–
The mGuard must be connected, i.e., the required connections must be working.
10.4.2
Local configuration on startup (EIS)
As of firmware version 7.2, initial startup of mGuard products provided in Stealth mode is
considerably easier. From this version onwards, the EIS (Easy Initial Setup) procedure en-
ables startup to be performed via preset or user-defined management addresses without
actually having to connect to an external network.
The mGuard is configured using a web browser on the computer used for configuration.
NOTE: The web browser used must support SSL encryption (i.e., HTTPS).
According to the default setting, the mGuard can be accessed via the following addresses:
Table 10-3
Preset addresses
Default setting
mGuard blade controller
The mGuard is preset to the "multiple Clients" stealth configuration. You need to configure
a management IP address and default gateway if you want to use VPN connections (see
Page 189). Alternatively, you can select a different stealth configuration or use another net-
work mode.
Network
Management IP #1
mode
Router
–
mGuard blade
Management IP #2
https://192.168.1.1/
Innominate Security Technologies
187