BRKT
Removing the clamp bracket
1. Remove the ground lead 1 and self-
locking nut 2 of the through tube, then
clamp brackets 3 and 4.
2. Remove the trim sensor 5.
NOTE:
Be sure to remove the ground lead 1 before
removing the self-locking nut 2.
3. Remove the spring 6, holder 7, and
pins 8.
6
7
4. Remove the tilt stop levers 9, distance
collar 0, collar A, and bushings B.
7-25
Bracket unit
8 8
0
S6AL7490
Installing the clamp bracket
1. Assemble the distance collar.
NOTE:
Make sure that the distance a shown is
30.3–30.4 mm (1.19–1.20 in).
2. Install the bushings 1, collar 2, distance
collar 3, and tilt stop levers 4.
4
3
1
a
S6AL7510
4
2
1
1
S6AL7525
6AL3J11