Troubleshooting The Ptt Unit - SELVA MARINE Grey Whale 200 EFI Service Manual

Table of Contents

Advertisement

Troubleshooting the PTT unit

Symptom 1: PTT unit does not operate
Symptom 2
PTT relay does not
operate
PTT motor does not
operate
Oil pressure does
not increase
WD: See the wiring diagram.
6AL3J11
Cause 1
PTT
switch
mal-
function
Short, open, or loose
connection
of
the
wiring harness
PTT relay malfunc-
tion
Short, open, or loose
connection
of
the
PTT motor lead
PTT motor malfunc-
tion
Blown fuse
Loose connection of
the battery terminal
Discharged battery
Manual valve
Manual valve mal-
opened
function
Insufficient PTT flu-
id
PTT fluid leakage
Clogged filter
Clogged fluid pas-
sage
Troubleshooting the power unit
Cause 2
Checking step
Check
switch.
Check
harness continuity.
Check
relay.
Check the PTT mo-
tor lead.
Disassemble
check the PTT mo-
tor.
Check the fuse.
Check the battery
terminal.
Check the battery.
Check the manual
valve.
Add sufficient fluid.
Check the PTT unit
for leakage.
Disassemble
check the PTT unit.
Refer
to
page
the
PTT
7-59
the
wiring
WD
the
PTT
7-58
7-36
and
7-35
8-5
3-17
3-17
7-30
3-13
7-30
and
7-30
9-24
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fin whale 225 efi

Table of Contents