Troubleshooting The Power Unit Using The Diagnostic Flash Indicator; Troubleshooting The Power Unit (Trouble Code Not Detected) - SELVA MARINE Grey Whale 200 EFI Service Manual

Table of Contents

Advertisement

TRBL
SHTG
Troubleshooting the power unit
using the diagnostic flash indicator
1. Connect the special service tool to the
outboard motor as shown.
L/W
NOTE:
When performing this diagnosis, all of the
electrical wires must be properly connected.
Diagnostic flash indicator B:
90890-06865
2. Start the engine and let it idle.
3. Check the flash pattern of the special
service tool to determine.
• Trouble code indication
Example: Normal condition
(no defective part or irregular process-
ing is found)
a: Light on, 0.33 second
b: Light off, 4.95 seconds
9-17
Troubleshooting
S6AL9020
• Trouble code indication
Example: The illustration indicates
code numbers 23 and 113.
a: Light on, 0.33 second
b: Light off, 4.95 seconds
c: Light off, 0.33 second
d: Light off, 1.65 seconds
1
1
c
a
d a
d
a
4. If a flash pattern listed in the trouble code
chart is displayed, check the malfunction-
ing part according to the flash pattern.
3
a
a
b
S6P29040E
6AL3J11