INSTALLATION
9. Install the bell housing cover attaching bolts and tighten to
specifications.
Tightening torque:
38-51
N.m (3.8-5.2
kgfem, 28-37
ft.lbf)
10. Install the dust cover (MT) or converter inspection plate
(AT).
Tightening torque:
Dust cover: 8-1 1 N.m (0.8-1.1
kgf-m, 5.9-4.1
ft-lbf}
Converter inspection plate: 2.5-3.6
N-m
(24-36
kgf-cm, 22.1-31.8
in-lbf)
11. Connect the ground cable to the engine.
12. Connect the fuel supply and return lines to the two fuel rail
fittings.
Tightening torque:
3 4 4 6 N.m ( 3 . 4 4 . 6 kgfem, 25-33.9
ft.lbf)
14. Connect both the Heated Oxygen Sensors (H02S).
15. Install the starter motor. (Refer to Section G.)
16. Lower the vehicle.
FRONT OF VEHICLE
13. Connect the three way catalytic converter to the exhaust
manifold. Tighten to specifications.