ELECTRICAL SYSTEM COMPONENTS
TRANSMISSION FLUID TEMPERATURE (TFT)
SENSOR
lnspection
1. Access TFT PID.
2. Monitor the TFT PID voltage as the engine warms to
normal operating temperature.
Specification:
3. If TFT PID does not increase as engine reaches normal
operating temperature, replace TFT sensor.
Replacement
The TFT sensor is a part of the main control valve body
wiring harness. (Refer to K-152.)
6BUOKX.201
Resistance (K)
- -
59.175
~
37.387
Temperature
PID Voltages (V)
10°C {50°F}
3.525
TURBINE SHAFT SPEED (TSS) SENSOR
20°C {68"F}
lnspection
1. Disconnect the TSS sensor connector.
2.
Measure the resistance between the terminals of the TSS
sensor.
3.095
30°C (86°F)
40°C { I 04°F)
-
50°C { I 22°F)
i
6 0 6 ~ {I 40°F}
70°C (1 58°F)
80°C
{I
76°F)
90°C { I 94"F}
-
1 00°C {212"F}
1 1 O°C {230°F)
Resistance:
64--120 ohms
3. If not as specified, replace the TSS sensor.
7BUOKX 035
Replacement
The TSS may be replaced only during a complete disassem-
bly of the transmission. (Refer to K-102.)
7BUOKX-202
2.623
24.21 5
-
2.149
16.043
- -
--
1.71
10.85
1.333
1.025
0.784
- -
0.599
0.458
0.352
120°C {248"F)
~
0.272
--
7.487
5.268
-
3.775
2.75
- -
. .
2.034
1.523
1.155
MFI 665-A
5BOUKX-033