Generator Pulley And Regulator Terminal Removal/Installation - Mazda B-Series 1997 Workshop Manual

Table of Contents

Advertisement

CHARGING SYSTEM
GENERATOR PULLEY AND REGULATOR TERMINAL
Removal 1 lnstallation
Note
The voltage regulatorlbrush holder assembly, generator pulley and regulator terminal are
serviceable. If the generator requires further service, it must be replaced as an assembly.
1. Remove in the order shown in the figure.
2. Inspect all parts and repair or replace if necessary.
3. Install in the reverse order of rernoval, referring to lnstallation Note.
I
I
MG1073-B
4BUOGX-023
1.
Pulley
2. Rear bracket
Installation Note
..............................
below
3. Regulator terminal
lnstallation Note
Pulley
1. Join the front and rear covers, and install the bolts.
Tightening torque:
4.1-6.7
N-m (41.9-68.3
kgf-cm,, 3 5 - 6 0 inelbf)
2.
Install the pulley and tighten the nut.
Tightening torque:
82-1 35 N-m (8.4-1 3.7 kgf-m, 6 1 0 - 1 00 ft-lbf)
4BUOGX-024

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents