Applications, Tips and Tricks
Voice Mail Set Up
Digital Ports
1. Program the following initial settings:
Program 100 – Set cabinet slot PCB type to "BDKU/BDKS 16 DKTs without Spkr OCA".
Program 200 – Assign stations to the slot and assign as voice mail. For example, 200~215 (for 16
ports). Set "Display DN" as the pilot number of the Voice Mail Hunt Group. This value should be
the same as "Number to Display" in Program 209.
Program 204 – Change station's parameters to Tone First, Adapter: BPCI. Set "Continuous DTMF"
to "Not Continuous." Copy the changes to all voice mail stations.
2. Install and program serial card BSIS in the Strata CTX.
TPI is required for iES32. A BSIS card must be installed in the Strata CTX.
Note
3. Install a serial cable between the BSIS card and the Stratagy (see CTX wiring diagrams in Strata CTX
Installation and Maintenance Manual, Peripheral Installation chapter).
4. Specify CTX BSIS output port # and set the port type to be "300 SMDI #0" and "RS-232".
5. Set the port attributes to:
Baud rate: 9600
Data Bits: 8
Parity: none
Flow control: 1
Wait timer: 0
Note
Refer to Programs 803, 804, 579 and 580.
6. Program 579
7. Program 580 – Set all CTX voice mail ports as SMDI integration.
8. Program Station Hunting Programs 209 and 218
Telephone Station Ports
1. Program 200 Station Data.
• FB19 VMID Code SMDI – Voice Mail ID number to send in SMDI and DTMF in-band integration
for forwarded and direct calls.
• FB22 MW to VM Port – Message Waiting center DN.
2. Program 579 System Voice Mail Data.
• Complete 11~15. See
3. Program 204 DKT Parameters.
• FB23 Mailbox Selection – Used for the Voice Recording Feature. Uses the VM ID from Program
200 if set to Auto or allows the user to enter any valid mailbox on Stratagy followed by .
4. Program 206 Phantom DN.
• FB06 VM ID Code – Voice Mail ID number to send in SMDI and DTMF in-band integration for
forwarded and direct calls.
• FB09 Message Center – Message Waiting center DN.
A-2
"System Voice Mail Data"
"Program 579"
on
page
13-89. Complete FB01~FB17.
on
page
13-89.