• Copy – After entering the source DN in the Primary DN field, click Copy and designate which FB
buttons to copy (click the DKT Phone header to select all). Enter the destination DN and click OK.
(Range is permitted.)
• Cross Copy – This button enables you to copy specific keys from a station's keypad to desired keys
of other station key pads. This function is available only with CTX WinAdmin R2.1 and above.
Refer to
"Cross Copy"
Distinctive Ringing – Release 1.3 and higher software enables you to set different incoming ringing tones
for internal and external calls on a Prime DN. Ten different tones are available. This can be set from
Programs 205, 213 and 215.
To set Distinctive Ringing, double click the button
that you want to set distinctive ringing. A dialog
box displays (shown right).
Click the drop-down arrows to set the External and
Internal tone pitches. The possible values are
shown in
Table
Notes
You must have the following versions of
processor boards for Distinctive Ringing:
CTX670: BECU1A, V.1C or later.
CTX100: ACTU1A, V.2D or later.
For any older versions of processor boards,
you can assign only "01" to Tone Pitch for
internal calls and you can assign only "11,"
"13," "15," or "17" to Tone Pitch for external
calls.
Ringing tone pitch has no effect on telephone
volume.
When programming External Ringing Repeat with a Distinctive Ringing Pitch, we recommend
that you use pitches "11" or "12" and not "17" or "18".
Incoming recall tone cannot be changed.
Calls to Tie lines adopt the internal call pitch.
Table 5-4
Tone No.
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04
on
page 5-19
for steps to use this function.
5-4.
Internal and External Call Ringing Tones
01
500 Hz 1 sec. On, 3 sec. Off, repeat
02
1300 Hz 1 sec. On, 1 sec. Off, repeat
11
500/640 Hz 1 sec. On, 3 sec. Off, repeat
12
500/640 Hz 1 sec. On, 1 sec. Off, repeat
13
860/1180 Hz 1 sec. On, 3 sec. Off, repeat
14
860/1180 Hz 1 sec. On, 1 sec. Off, repeat
15
1300/1780 Hz 1 sec. On, 3 sec. Off, repeat
16
1300/1780 Hz 1 sec. On, 1 sec. Off, repeat
17
860/1180 Hz 0.5 sec. On, 1300/1780 Hz 3 sec. Off, repeat
18
860/1180 Hz 0.5 sec. On, 1300/1780 Hz 1 sec. Off, repeat
Frequency and Cadence
Station
Assignment