Toshiba Strata CTX28 Programming Manual page 388

Hide thumbs Also See for Strata CTX28:
Table of Contents

Advertisement

Telephone Button Programming
300 Series Programs
Table 13-28
Programs 303~315 (continued)
Button
Sequence
312-01
DID Number
313
Caller ID Assignment
" "
C‚yq
,
313-00
Trunk Number
C‚yq
n,
,
313-01
Signalling Method
A7
C‚yq
, n,
313-02
Signalling Contents
A7
C‚yq
, n,
313-03
CLASS Equipment
Position
A7"
, xxyyzz,
315
T1 Trunk Card
" "
C‚yq
,
315-00
T1 Equipment
Location
C‚yq
xxyy,
315-01
Coding Format
A7
C‚yq
, n,
315-02
Frame Format
A7
C‚yq
, n,
315-03
Time Slots
13-64
Value(s)
n =
up to seven digits
n =
1~64 (CTX100)
1~96 (CTX670 Basic)
1~264 (CTX670 Exp.)
n =
1. None (default)
2. ANI/DNIS-MCI
3. ANI/DNIS-Sprint
4. CLASS (Caller ID)
n =
1. ANI and DNIS (default)
2. ANI only
3. DNIS only
4. DID only
xx =
Cabinet 01 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
C‚yq
yy =
Slot 01~8 (CTX100),
01~10 (CTX670)
zz =
Circuit 01~08
xxyy
xx = Cabinet 01,
yy = slot 01, 03, 05, or 07
...or xx = Cabinet 02~07,
yy = slot 01, 03, or 05
n =
1. None
2. PZC
3. B8ZS (default)
4. ZCS
n =
1. None
2. SF mode
3. ESF mode (default)
n =
1. None
2. 8 Time Slots (default)
3. 16 Time Slots
4. 24 Time Slots
DID Number to be deleted.
This program assigns Caller ID circuits to the CO Line to which the
circuit is connected. The ANI, DNIS, DID formats for TI and analog
DID CO Lines are also defined.
Enter the Trunk Number.
Specify the format for the interface being used.
Specify the contents of the ANI/DNIS format.
If the CLASS type is chosen, the trunk must be assigned to a Caller
ID circuit. Enter the RCIU/RCIS equipment number as xxyyzz.
Notes
CLASS equipment numbers are required when assigning a trunk
to a RCIU/RCIS circuit.
It can also be used to display the equipment location of existing
caller ID circuit to trunk assignments. Example: If the trunk should
be connected to a caller ID circuit (RCIU/RCIS) in cabinet shelf 5,
slot 2, circuit 3, enter 050203.
This command assigns T1 Trunk Card Data to the system.
Enter the RDTU PCB equipment location as xxyy:
Example: If the RDTU is installed in cabinet shelf 5, slot 3, enter
0503.
Cabinet numbers:
CTX100: Select 01 for Base and Expansion cabinet.
CTX670: Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
CTX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670: Select 01~08 for Base slots and 01~10 for Expansion slots.
Select the Coding Format.
Select the Frame Format.
Set the number of Time Slots to be used.