Station PDN Auto-programming

When auto programming recognizes installed station PCBs, it assigns PDNs in numerical order as follows:
• Auto programming assigns PDNs to station PCB equipment numbers (cabinet, slot, circuit) in
equipment number order. All installed station PCB circuits will be assigned a PDN regardless of the
circuit type, digital (BDKU/BDKS, PDKU) or analog (RSTU).
• PDN 200 or PDN 2000 (depending on the system size) is assigned to the station circuit having the
lowest equipment number in the system, then the PDN is incremented by one digit and assigned to the
next highest station equipment number and so on. See
• Program 205 Feature Button Setting – A Primary DN (PDN) is assigned to
telephone according to its equipment number (cabinet, slot, circuit) position. DND is assigned to FB20
on 20-button telephones and is not assigned on 10- and 14-button telephones.
Table 1-2
Auto-Programming for Station Primary Directory Number
CTX100 and CTX670 without BBMS
First digit
and BEXS Installed on Processor
Primary DNs (3-digits)
2
200~299 depending on quantity of station
PCBs installed
Primary DN (3-digits)
3
300~399 depending on qty. of station
PCBs installed
CO Line Auto-programming
Table 1-3
shows the CO line PCBs that will be recognized and set in Program 100 during auto-
programming. The default data for CO line Incoming Line Groups (ILG), Outgoing Line Groups (OLG),
and CO line service type is set as shown in
PCBs must be installed per the rules in the CTX I&M manual, Configuration Chapter,
Important!
Worksheet 6 and Worksheet 7.
Table 1-3
Auto-Programming for CO line PCB Recognition (Program 100)
PCB
PCB Name

Code

000
-
001
RCOU, RGLU
005
RCOU+RCOS
006
RDDU
007
RDTU2
008
RDSU
Strata CTX Programming - Part 1: Getting Started 6/04
Table
PCB Circuit Type
Parameter setting
No PCB or RRCU
4 analog Loop or
ground start lines
8 analog loop start
lines
4 analog DID lines
PCM Highway:
16 or 24 digital T1
lines
16 or 24
4 Standard telephone
and for digital
telephone
Strata CTX Programming Guidelines
Step 1: Use Default Auto-programming to Start Up
Table
1-2.
CTX670 with BBMS and BEXS
Installed on Processor (First Digit is 2)
Primary DNs (4-digit)
2000~2571 depending on qty. of station PCBs
installed
1-4.
None or Remote cabinets
Direct Incoming Termination (DIT)
lines
Direct Incoming Termination (DIT)
lines
Direct Inward Dial lines
T1 Direct Incoming Termination (DIT)
lines
1
Standard telephone and DKT2000
and DKT3000 without S-OCA
(DKT3000 limitations: DKT2000, 16
character LCD display on DKT3000,
DKT3000 LCD Feature key does not
function, DKT3014 large screen LCD
does not display).
%
on each digital
Comments