Door Lock Control Assignment - Toshiba Strata CTX28 Programming Manual

Hide thumbs Also See for Strata CTX28:
Table of Contents

Advertisement

Services
External Devices
F
IELD
06 Day1 Destination
07 Day2 Destination
08 Night Destination
576 Door Phone Night Ring Over External Page
This assignment sets the Page Group that should ring during the system Night Mode when a door phone
button is pressed. The assignment can be made for Tenant 1 only.
F
IELD
00 Tenant Number
01 Page Group Number

508 Door Lock Control Assignment

This assignment is used to configure up to 10 door lock control relays. The contacts of these relays are
used to control electrical door locks. One door lock relay can be assigned to each of the eight Door Phone
Control Boxs (DDCB, Port -B) and/or one to each of the two BIOU PCBs (any one of the four control
relays).
If a door lock is assigned to a DDCB, the second jack (Port B) will provide the door lock relay
Note
contacts. This jack can not be used to connect an MDFB door phone.
F
IELD
00 Door Lock Number
01 Interface Type
9-70
D
ESCRIPTION
Select the type of destination that should ring when the door phone button is
pressed during the system Day1, Day2 or Night mode.
Possible values: None (default), DN or
Paging Group 1~4 (CTX100); 1~8 (CTX670 Basic); 1~16
(CTX670 Exp.)
Enter the Destination Number. If the ring destination type is a PDN or PhDN,
enter the directory number. If the ring destination type is Page, enter the Page
Group number.
Possible values: Up to 5 ASCII characters (default = no value)
D
ESCRIPTION
Select the system Tenant number to be assigned Door Phone to Page Group/
Night Ringing.
Possible values: 1(CTX100 and CTX670) (default = no value)
Select the system Page Group number that should ring for the selected Tenant
when a door phone button is pressed during the system Night Mode.
Possible values: 0~4 (CTX100), 0~8 (CTX670 Basic), 0~16 (CTX670 Exp.)
(default = 0)
D
ESCRIPTION
Enter the door lock control number to configure.
Possible values: 1~4 (CTX100); 1~5 (CTX670 Basic);
1~10 (CTX670 Exp.), (default = no value)
Enter the system Page Group number that should ring for the selected tenant
when a door phone button is pressed during the system Night Mode.
Possible values: None (default), BIOU or DDCB
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx670Strata ctx100-sStrata ctx100

Table of Contents