• Select and right mouse click the appropriate SmartMedia drive, for example, drive E or G in some
computers.
• Click Properties.
• Under General tab, in the Label field enter label name (in this case PRGUPDATE).
6. Pull out the SmartMedia card and physically label it "CTX670, MXnnn" or whatever software version
you are updating to.
Note
After completing Steps 1 and 2 above you should have two SmartMedia cards:
One card containing the CTX backed up database file: PROGDATA\default.dat
One card having the volume label "PRGUPDATE" and containing the CTX software Update
file: PROGRAM\nhs.prg
Step 3: Update CTX670 software
1. Insert the SmartMedia card containing PROGRAM\nhs.prg file into the Strata CTX processor
SmartMedia socket.
2. From the programming telephone enter Program 911, and press
(UPDATE) and then press
interrupt the CTX system operation.
• If FB07-LED is flashing green, it indicates that the Update process is in progress.
• If FB07-LED is flashing red, it indicates an error. This could be caused by a corrupt or incorrect
nhs.prg file or a defective SmartMedia card. Make sure it is a CTX670 nhs.prg file and not a
CTX100 file.
• You can now check the Update progress using FB02 (Total) and FB03 (Copied) to view data block
status. Periodically switch between FB02 and FB03 to view the data blocks.
• When FB07-LED is solid green with periodic short blinks, it indicates the first part of Update
completed successfully (2 to 10 minutes).
3. After FB07 is on solid green with a periodic wink, press
!
dial
(TRIAL) and then press
4. Pull out the SmartMedia card labeled PRGUPDATE (which includes PROGRAM/nhs.prg file).
5. Insert the SmartMedia CARD labeled "Strata CTX Backup data" into processor/ SmartMedia socket.
The SmartMedia LED on the processor begins to blink.
The "Strata CTX Backup data" SmartMedia card is the card you previously made that includes the
Strata CTX programmed data in the default.dat file under the PROGDATA folder. If this is not done
before starting Clear-reboot, all programmed data will be lost.
The next operation will take the system out of service for 10 minute to an hour depending on the size of
the CTX database.
6. From the programming telephone enter Program 911 and press
(CLRREBOOT) and then press
version from standby to active and restore Backup data.
This operation will take the system out of service for 10 minutes to an hour or more
CAUTION!
depending on the CTX database. Do not skip any steps or Update will fail.
Notes
Strata CTX Programming - Part 3: Telephone Button Programming 6/04
C‚yqÃ
C‚yqÃ
once. Pressing
C‚yq
. This will change the status of the Standby Flash Memory to trial.
C‚yq
. This will Clear-reboot the system to switch the new software
ROG
7
. Press
twice will cause the Update to fail. This will not
C‚yq
, while in Program 911. Press
C‚yq
7
; Press
Maintenance
Local Update
and dial
7$
and
"
and dial
14-7