Telephone Button Programming
300 Series Programs
Table 13-29
Programs 316~317 (continued)
Button
Sequence
317-01
Equipment Number
A7
, xxyyzz,
317-02
Protocol
A7
C‚yq
, n,
317-03
ILG
A7"
C‚yq
, n,
317-04
OLG
A7#
C‚yq
, n,
317-05
Connection Format
A7$
C‚yq
, n,
317-06
Bearer Svc - Speech
A7%
C‚yq
, n,
317-07
Bearer Svc - 3.1 KHz
Audio
A7&
C‚yq
, n,
317-08
Bearer Svc - 7 KHz
Audio
A7'
C‚yq
, n,
317-09
Bearer Svc -
Unrestricted 64K
A7(
C‚yq
, n,
317-10
Bearer Svc -
Unrestricted 56K
A7 
C‚yq
, n,
317-11
Bearer Svc -
Unrestricted 2x64K
A7
C‚yq
, n,
317-12
Outgoing B Ch Select
A7
C‚yq
, n,
13-66
Value(s)
xx =
CTX670
yy =
C‚yq
Cabinet (01~07)
zz =
Slot (01~10)
Circuit (01~08 or 01~24)
or
CTX100
Cabinet (01)
Slot (01~08)
Circuit (01~04)
n =
1. National ISDN
2. ETSI
3. TTC
4. National ISDN Nortel
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
n =
1. Point to Point
2. Point to Multi Point
n =
1. Enable (default)
2. Disable
n =
1. Enable (default)
2. Disable
n =
1. Enable
2. Disable (default)
n =
1. Enable (default)
2. Disable
n =
1. Enable
2. Disable (default)
n =
1. Enable
2. Disable (default)
n =
1. Explicit
2. Preferred (default)
3. Any Channel
Enter the equipment number xxyyzz to which the ISDN BRI Trunk is
to be assigned.
Example: If the RBUU is installed in cabinet shelf 5, slot 3, enter
050301 for circuit 1.
Cabinet numbers:
CTX100 – Select 01 for Base and Expansion cabinet.
CTX670 – Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
CTX100 – Select 01~04 for Base slots and 05~08 for Expansion
slots.
CTX670 – Select 01~08 for Base slots and 01~10 for Expansion
slots.
Select the ISDN protocol. Only Bearer capabilities specified by the
protocol can be entered in this field. The Initial value for ISDN
Protocol corresponds to information set in the hardware level.
National ISDN = North America, ETSI = England and TTC = Japan.
ILG assignments must be made for basic ISDNs to process the calls
being received.
OLG assignments must be made for basic ISDNs to process the calls
being originated.
Identify connection format with the PSTN is 1- Point-to-Point or 2-
Point-to-Multipoint.
Enable speech capability.
Enable 3.1 KHz audio capability.
Enable 7 KHz audio capability.
Enable one of the unrestricted capabilities.
Select originating B Channel method.
Explicit – Channel is indicated, and no alternative is acceptable.
Preferred – (default) Channel is indicated, and any alternative is
acceptable.
Any Channel – Channel is indicated, and any channel is
acceptable.