Trunk Timer - Toshiba Strata CTX28 Programming Manual

Hide thumbs Also See for Strata CTX28:
Table of Contents

Advertisement

Trunks
300 Trunk Assignment

308 Trunk Timer

Prerequisite Program:
These commands assign Trunk timers.
1. Complete the
Record Sheet"
2. From the Program Menu, click
Trunk > Assignment, then click the
Timer tab. The Trunk Timer and
DIT Assignments screen displays
(shown right).
3. Enter Trunk equipment number
field. Enter Program 308 data.
• List – to view a summary list of
programmed Trunks timers.
• Copy – to copy to trunk timer
ports.
4. Click Submit.
F
IELD
Line No.
01 Auto Release
02 Short Flash
03 Long Flash
6-10
300
page 6-6
"Trunk Timer/DIT
on
page
D-27.
D
ESCRIPTION
Enter the trunk equipment number.
Possible values: xx = Cabinet 01~07; yy = Slot 01~10; zz = Circuit 01~08 or
Note
Equipment numbers are required when assigning a new trunk to the system. It
can also be used to display the equipment location of existing trunks.
Select the Automatic Release timing.
Possible values: Disable, Detect 95ms or Detect 450ms (default)
Note
Select Disable if the CO does not send the automatic release signal to the loop
start trunk.
Select Short Flash Time
Possible values: 0~15, where 1 = 100msec. (default = 5, which is .5 seconds)
When a telephone initiates the short flash signal to the CO line it is connected to (using
the short Flash feature button or access code #450) the duration of a short flash is
determined by this command. Normally this signal is used to hook flash a centrex line.
The short flash range is 0 to 1.5 seconds in increments of 0.1 seconds.
Select Long Flash Time.
Possible values: 0, 5, 10, 15, 20, 25 and 30, where 5 = .5 seconds. (default = 5)
When a telephone initiates the long flash signal to the CO line it is connected to (using
the Long Flash feature button or access code #451) the duration of a long flash is
determined by this command. Normally this signal is used to disconnect the line. The
long flash range is 0 to 3 seconds in increments of 0.5 seconds. Possible values: 0=no
flash, 5=.5 sec., 10=1sec. 15=1.5 sec., 20=2 sec., 25=2.5 sec., 30=3 sec.
zz = T1 Circuit 01~24 (CTX670)
xx = Cabinet 01; yy = Slot 01~08; zz = Circuit 01~24 (CTX100)
(default = no value)
0 = no flash, 1 = .1 sec., 2 = .2 sec. – 15=1.5 sec. 5 is the most
common duration of a hook flash signal
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx670Strata ctx100-sStrata ctx100

Table of Contents