Table 1-5
Auto-Programming of Miscellaneous Line Parameters
Item
DIT line ringing assignment
Program 310
DID numbers - not assigned.
Program 309
Format Setting for DIT (T1)
Setting for CAMA
Setting for ISDN BRI CO
Setting for ISDN PRI CO
Setting for E&M Tie lines
The destination of Program 318, No Calling Party Number and Out Of Search for DID number, is assigned
to the first Primary DN of the system (200 or 2000) in the all system operating modes (Day1,Day 2, and
Night).
The DIT line (ground and loop) destinations of all trunks which generated automatically are set as the first
PDN 200 or 2000 depending on the system size – see

BIPU Settings

Table 1-6
BIPU-M Automatic Settings
Item
Card Type
IP Address (BIPU)
Subnet mask (BIPU)
Default gateway
Strata CTX Programming - Part 1: Getting Started 6/04
All of the ringing destinations of DIT lines are the first PDN:
PDN 200 for CTX100 and 2-cabinet CTX670
PDN2000 for 2~7 cabinet CTX670.
The destination of DID is not assigned. DID numbers and ringing
destinations must be assigned manually from CTX WinAdmin or the
programming telephone.
Zero Code Suppress = B8ZS, Frame Format = ESF.
The destination of internal notification is the first DN 200 or 2000 in the all
operation mode (DAY1, Day2, and Night).
Common D channel is not assigned. 1 channel group is assigned to each
BRI PCB installed. The channel group number is assigned in order to each
BRI interface in the order in which the BRI PCBs are installed. The
destination of DID is not assigned.
Common D channel is not assigned. 1 channel group is assigned to each
PRI PCB installed. The channel group number is assigned in order to each
PRI interface in the order in which the PRI PCBs are installed. The
destination of DID is not assigned.
The node number and the other setting for networking are not assigned
automatically
Table
Description
Card Type
IP address of BIPU
Subnet mask of BIPU
substrate
Default gateway of BIPU
substrate
Strata CTX Programming Guidelines
Step 1: Use Default Auto-programming to Start Up
Settings
1-4.
Settings
BIPU
In the order of smallest number of the slot
where BIPU is inserted
192.168.254.200
.201
.202/.......
Private address will be set.
255.255.255.0
0.0.0.0