Cbc Time Zones - Toshiba Strata CTX28 Programming Manual

Hide thumbs Also See for Strata CTX28:
Table of Contents

Advertisement

Trunks
ISDN
F
IELD
03 Facility Code
04 Service Parameter
05 Network ID
06 ILG
07 OLG
08 Min Calls Zone 1
09 Max Calls Zone 1
10 Min Calls Zone 2
11 Max Calls Zone 2
12 Min Calls Zone 3
13 Max Calls Zone 3

324 CBC Time Zones

This command assigns Call-by-Call Time Zone.
F
IELD
Channel Group
01 Start Zone 1
02 Start Zone 2
03 Start Zone 3
6-30
D
ESCRIPTION
Enter the supplied Facility code value from the PSTN. If no data is entered in this field,
any previously entered data is deleted.
Possible values: 00~31(default = no value)
Enter the Service parameters supplied from PSTN. If no data is entered in this field, any
previously entered data is deleted.
Possible values: Up to 5 digits (default = no value)
Enter the Network ID code supplied from PSTN (this field is required if you selected
"Inter LATA Out WATS" Type of Service. If no data is entered in this field, any previously
entered data is deleted.
Possible values: 3 to 4 digits (default = no value)
Specify the ILG for this facility.
Possible values: 0~32 (CTX100), 0~50 (CTX670 Basic),
0~128 (CTX670 Exp.), (default = 0)
Specify the OLG for this facility.
Possible values: 0~32 (CTX100), 0~50 (CTX670 Basic),
0~128 (CTX670 Exp.), (default = 0)
Select the minimum number of Bch in Time Zone 1.
Possible values: 0~47 (default = 0)
Select the maximum number of Bch in Time Zone 1.
Possible values: 0~47 (default = 47)
Select the minimum number of Bch in Time Zone 2.
Possible values: 0~47 (default = 0)
Select the maximum number of Bch in Time Zone 2.
Possible values: 0~47 (default = 47)
Select the minimum number of Bch in Time Zone 3.
Possible values: 0~47 (default = 0)
Select the maximum number of Bch in Time Zone 3.
Possible values: 0~47 (default = 47)
D
ESCRIPTION
Channel Group Number
Possible values: 1~32 (CTX100), 1~48 (CTX670 Basic),
1~128 (CTX670 Exp.), (default = no value)
Enter the Time Zone Starting Time (hhmm).
Possible values: hh = 00~23, 99 (hour)
mm = 00~59, 99 (minutes)
9999 = delete time zone, (default = no value)
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx670Strata ctx100-sStrata ctx100

Table of Contents