Node Id Detail Information - Toshiba Strata CTX28 Programming Manual

Hide thumbs Also See for Strata CTX28:
Table of Contents

Advertisement

Services
Strata Net QSIG Over IP

672 Node ID Detail Information

System Availability: Not available with CTX28
This command assigns the parameters to the is used by BIPU-Q1As at the remote nodes connecting to the
BIPU-Q1A in the local node over IP Private Networking.
Important!
• These parameters must match all nodes on the IP network.
• When setting Node ID assignments on an IP QSIG network, the Node ID assignment settings for
each node on an end-to-end connection must be the same.
• Whenever Node ID assignment change are made for IP telephones or IP QSIG Node IDs, Toshiba
recommends pressing the reset button on the BIPU to assure the changes take effect.
1. Click Services > Networking >
Network Over IP.
2. Click Detailed Info tab.
3. Enter Program 672 data.
4. Click Submit.
F
IELD
Remote Node ID
01 IP Protocol Type
02 Voice Packet Table
9-62
D
ESCRIPTION
Node ID of remote CTX connected to this CTX with BIUP-Q, IP networking.
Possible values: Up to six digits.
Select the desired IP protocol to be used by the BIUP-Q1A at the remote node.
This parameter must match on both nodes of an end-to-end connection on the IP
network.
Possible values: IPQSIG (default), H.323 (Do not use; H.323 is not available)
Select the desired voice packet configuration table number (programmed in this
CTX) to be used by the BIUP-Q1A at the remote node. Voice Packet tables are
configured in Program 152
Possible values: 1~128 (CTX100 and CTX670 Basic)
1~256 (CTX670 Exp.)
(default = 1)