300 Series Programs
Table 13-26
Programs 300~302
Button
Sequence
300
Trunk Assignment
"
Cyq
,
300-00
Line Number
Cyq
n,
300-01
Line Equipment No.
A7
Cyq
, xxyyzz,
300-02
Incoming Line Group
A7
Cyq
, n,
300-03
Outgoing Line Group
A7"
Cyq
, n,
300-04
Dial Mode
A7#
Cyq
, n,
300-05
Signaling
A7$
Cyq
, n,
300-06
Start Method
A7%
Cyq
, n,
300-07
Release Supervision
A7&
Cyq
, n,
300-08
Answer Supervision
A7'
Cyq
, n,
300-09
Trunk Name
300-10
External Ring Repeat
A7
Cyq
, n,
Strata CTX Programming - Part 3: Telephone Button Programming 6/04
Value(s)
n =
1~64 (CTX100)
1~96 (CTX670 Basic)
1~264 (CTX670 Exp.)
xx =
Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
yy =
Slot 01~8 (CTX100),
01~10 (CTX670)
zz =
Circuit (01~04)
...or zz = T1 Circuit 01~24
(CTX670).
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
(default = 0)
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
(default = 0)
n =
1. Rotary Dial 10PPS
2. Rotary Dial 20PPS
3. DTMF (default)
n =
1. DID
2. Loop (default)
3. Ground
4. Tie
5. LP (Japan)
6. SR (Japan)
7. ACU (UK)
n =
1. Immediate Start
(default)
2. Timing Start
3. Wink Start
n =
1. Received
2. Not Received (default)
n =
1. Received
2. Not Received (default)
n =
Up to 14 digits
n =
1. Supplied (default)
2. Not Supplied
Telephone Button Programming
Summary
This command assigns an analog or T1 trunk (line) and its
parameters to the system.
Enter the Line Number.
Enter the line equipment number as xxyyzz. Equipment numbers are
required when assigning a new trunk to the system. It can also be
used to display the equipment location of existing trunks.
Example: If the trunk should be connected to an RCOU in cabinet
shelf 5, slot 2, circuit 3, enter 050203.
Cabinet numbers:
•
CTX100 – Select 01 for Base and Expansion cabinet.
•
CTX670 – Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
•
CTX100 – Select 01~04 for Base slots and 05~08 for Expansion
slots.
•
CTX670 – Select 01~08 for Base slots and 01~10 for Expansion
slots.
Assign the trunk to Incoming Line Group. Two-way trunks need to be
members of one incoming and one outgoing line group.
Assign the trunk to Outgoing Line Group. Two-way trunks need to be
members of one incoming and one outgoing line group.
Enter the Dial Mode.
•
DP 10 PPS = Rotary Dial, 10 PPS
•
DP 20 PPS = Rotary Dial, 20 PPS
Enter the signalling type.
Enter the Start Method. This setting defines the start protocol method
used between the PSTN and this trunk. For DID/Tie trunks.
Enable Release Supervision from the CO.
Enable Answer Supervision from the CO.
Enter the trunk name.
Note
This function is accessible only through CTX WinAdmin.
Supply the External Ringing Signal pattern to stations. For behind
PBX/Centrex trunks.
300 Series Programs