System
This chapter provides Strata CTX system programming information for programmers using the CTX
WinAdmin programming interface.

100 Cabinet Slot PCB Assignments

Prerequisite Program:
All Printed Circuit Boards (PCBs), excluding the system processors, are assigned to cabinet slots. The
processor PCBs have dedicated slots in the Base Cabinet which do not require this assignment. The system
provides one Base Cabinet and up to six Expansion Cabinets. The Base Cabinet provides eight slots and
each of the six Expansion Cabinets provide 10 slots for a total of 68 slots.
1. Fill out the
"Card Assignment Record Sheets"
2. From the Program Menu click System >
Card Assignment. The Card Slot
Assignment screen displays (shown
right).
3. Cabinet (01~07) – Select the two digit
cabinet number to be assigned. The
cabinet and slot number appear in the
cab/slot field. Select 01 for Base and
Expansion cabinet (CTX100).
Select 01 for Base and 02~07
respectively for each Expansion cabinet
(CTX670).
4. Slot (01~10) – Select 01~04 for Base
Slots and 05~08 for Expansion slots
(CTX100).
Select 01~08 for Base Slots and 01~10
for Expansion Slots (CTX670).
The CTX100 ACTU built-in relay is programmed as relay 5. For this relay operation, BIOU2 is
Note
installed as default in a virtual equipment position; Cabinet 2, Slot 5, PCB code 20 in Program 100.
To install an actual BIOU2 and disable the ACTU built-in relay, use the programming telephone to
remove the virtual BIOU2 and then install the actual BIOU2 in Cabinet 01/Slot 01~08 in the normal
manner.