FIP1.72 Over Heat 042-700/Ready to Print 142-700
Step
Possible causative parts:
KIT FEEDER ASSY (PL3.2.99)
PWBA MCU (PL9.1.20)
Checking the room temperature
1
Is the room temp. Over 32 degrees C?
Checking the printing
2
Did the client print the large volume of printing?
Checking the printing after cool down of five minutes.
3
Does the error still occur when printing?
Checking the PWBA MCU
4
Reseat the PWBA MCU.
Does the error still occur when printing?
Checking after replacing the PWBA MCU
5
Replace the PWBA
Does the error still occur when printing?
Version 1 2008.02.15
Check
1 - 272
Chapter 1 Troubleshooting
Yes
Change the room
or cool down the
room
Go to step 3.
Go to step 4.
Go to step 5.
Replace the KIT
FEEDER ASSY.
(Refer to Removal
40/Replacement
4)
No
Go to step 2.
Go to step 4.
End of work
End of work
End of work