Replacement 8
10) Install the DUCT AIRFLOW to the printer by slipping in its rear end underneath the frame.
11) Mate the two hooks of the DUCT AIRFLOW with the holes of the SHIELD LVPS. Move the
DUCT AIRFLOW frontward until it is secured onto the SHIELD LVPS at the two hooks and
one tab.
Go to the next replacement step:
Replacement 12 FAN (PL9.1.10)
Version 3 2008.05.30
ROS (PL5.1.99)
10)
Chapter 3 Removal and Replacement Procedures (RRPs)
SHIELD LVPS
FRAME
DUCT AIRFLOW
hook
hook
3 - 112
11)
tab
Zna03335KA