Dell 3130cn Service Manual page 445

Color laser printer
Hide thumbs Also See for 3130cn:
Table of Contents

Advertisement

Item
REGI CLUTCH ON
Version 3 2008.05.30
NOTE: When performing operation for five minutes or longer with the
front cover open, remove all toner cartridges, and cover the drum to
avoid exposure to light.
1)
Turn on the power and enter the CE Diag.
2)
Execute the REGI CLUTCH ON. Upon hitting the Start but-
ton, the operating noise of the clutch will be heard.
3)
Click the stop button to stop the clutch.
Combination test is as follows.
NOTE: The regi roll rotates when the PH MOTOR ON (FULL) and the
REGI CLUTCH ON are executed. This procedure is for the technical
staff.
1)
Turn on the power and enter the Diagnostic Mode.
2)
Open the Front Cover.
3)
Cheat the safety Interlock System.
4)
Execute the PH MOTOR ON (FULL) and the REGI CLUTCH
ON.
5)
Confirm the Regi Roll rotation.
6)
Click the stop button to stop the clutch.
7)
Remove the cheater and close the Front Cover.
2 - 91
Chapter 2 Operation of Diag.
Confirmation procedure
Regi Roll
Zna02028KA

Advertisement

Table of Contents
loading