Flows 81 Vertical blank lines (White stripes in paper transport direction)
13
13
Check the print data
which the problem
generated.
Version 3 2008.05.30
13
13
Mnt01102KA
Checking the Vertical blank lines.
Print the Contamination Check
page.
Is the image printed
Yes
correctly?
Checked by [Test Print] -
[contamination Check]
in diagnosis.
Remove the foreign
substance.
13
Random
13
Periodic
No
Checking the foreign
substance and damage.
Open the Front cover;
check the surrounding area
of the print cartridges and
the TRANSFER ASSY
Are there
Yes
any foreign
substances?
1 - 136
Chapter 1 Troubleshooting
13
13
Mnt01103KA
No
A