Adjusting system timing

Do not change the following controls unless directed. If your system does
not appear to be functioning properly, please contact your dealer for
assistance.
1. Expand Options > Troubleshooting.
2. Set the Minimum length of the Flash to the shortest duration considered
to be an intentional Flash from a local extension. Choices range from 50
ms. to 600 ms.
3. Set the Maximum length of the Flash to the longest duration considered
to be an intentional Flash from a local extension. Choices range from 120
ms. to 1 sec.
Most phones emit a 600 ms Flash signal when the Flash or Link button
is pressed.
4. Set the Transmitted Flash length to the duration of the Flash sent by the
TalkSwitch system to the telephone company in order to control
telephone company services. Choices range from 80 ms. to 600 ms.
5. Set the Double Flash time to the maximum interval between two Flash
signals for the TalkSwitch system to recognize them as a Flashintended
for the telephone company. If the interval is less than or equal to the
T A L K S W I T C H U S E R G U I D E