4.5.13 Uneven image density
Scanner section
Section
Step Check item
Scanner section
1
(Front side)
2
3
4
5
Section
Step Check item
Scanner section
1
(Back side)
2
3
4
5
Are the mirrors, lens, ADF glass and
document glass dirty?
Is the shading sheet under the
contact cover dirty?
Is the LED lamp dirty or deteriorated?
Do the connection from CCD
Scanner board Main control board
LPH board LPH connect board
LED unit remain intact?
Is the trouble settled with above
steps?
Are the mirrors, lens, DADF glass
and document glass dirty?
Is the shading plate for DADF
scnanning section dirty?
Is the LED lamp dirty or deteriorated?
Do the connection from CCD
R-Scanner board RADF board
Main control board LPH board
LPH connect board LED unit
remain intact?
Is the trouble settled with above
steps?
Result Remedy
YES
Clean.
If the trouble is not settled
by cleaning, adjust the
background level.
YES
Clean.
If the trouble is not settled
by cleaning, adjust the
background level.
YES
Clean. / Replace.
NO
Reconnect / Replace harness
NO
1. Replace scanner board.
2. Replace main control board.
3. Replace LPH board.
4. Replace LPH connect board.
5. Replace LPH.
Result Remedy
YES
Clean.
If the trouble is not settled
by cleaning, adjust the
background level.
YES
Clean.
If the trouble is not settled
by cleaning, adjust the
background level.
YES
Clean. / Replace.
NO
Reconnect / Replace harness
NO
1. Replace R-Scanner board.
2. Replace RADF board.
3. Replace main control board.
4. Replace LPH board.
5. Replace LPH connect board.
6. Replace LPH.
4-41