Muratec MFX-2550 Field Engineering Manual page 262

Hide thumbs Also See for MFX-2550:
Table of Contents

Advertisement

No.
Symptom
22. Does the voltage level of P82-6 on
3
Documents jam
frequently.
The LCD shows
"Please reset the
document."
23. If you replace the DS2 sensor, the
24. Is the separation roller dirty?
25. Is the separation pad dirty?
Documents skew 1. Have the document guides been
4
2. Did you place different size docu-
3. Are there any foreign objects on the
4. Have the separator roller and the
5. Are there any problems with on
6. Is the guide outer deformed?
5
Documents get
1. Are they thin documents?
wrinkled or torn
frequently.
2. Are there any foreign objects on the
3. Do the documents get wrinkled or
4. Has the entry area of the guide
5. Is the separation pad dirty?
What to confirm
the main control panel change to
+0V when the DS2 is ON, and to
+5V when the DS2 is OFF?
symptom will be fixed.
adjusted properly?
ments at the same time?
paper pass?
pad separator been worn out?
the installations and operations of
the separator roller and the pad
separator?
document tray?
torn around the feeding entry area?
outer been deformed?
Yes
Check No. 23.
No
Check No. 24.
Yes
Replace the DS2.
No
Replace the main control board.
Yes
Replace the separation roller.
No
Check No. 25.
Yes
Replace the separation pad.
No
Replace the machine.
Yes
Check No. 2.
No
Re-adjust the guides properly.
Set only the same size documents.
Yes
No
Check No. 3.
Remove the objects.
Yes
No
Check No. 4.
Yes
Replace them.
No
Check No. 5.
Yes
Check their operations.
No
Check No. 6.
Yes
Fix or replace it.
No
Replace the machine.
Yes
Recommend customer to use the docu-
ment glass.
No
Check No. 2.
Remove the objects.
Yes
No
Check No. 3.
Yes
Check No. 4.
No
Check No. 6.
Yes
Repair or replace it.
No
Check No. 7.
Yes
Replace the separation pad.
No
Replace the machine.
4-49
Countermeasure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-2570

Table of Contents