Muratec MFX-2550 Field Engineering Manual page 62

Hide thumbs Also See for MFX-2550:
Table of Contents

Advertisement

Machine Parameter 020
Initial
Switch
Setting
7
0
Mirror carriage standby
position adjustment
6
0
5
0
Adjusts the number of the
4
0
steps from the home sensor
3
0
of the mirror carriage OFF
2
0
to the standby position.
1
0
0
0
1 step = 2 / 600 dpi
Machine Parameter 021
Initial
Switch
Setting
7
0
Mirror carriage transfer mode
position adjustment
6
0
5
0
Adjusts the number of the
4
0
steps from the home sensor
3
0
of the mirror carriage OFF
2
0
to the transfer mode position.
1
0
0
0
1 step = 2 / 600 dpi
Adjust
(0.0847 mm)
Adjust
(0.0847 mm)
3-10
Usage/Comments
Switch
76543210
127 steps 01111111
:
00100000
:
00010000
:
00001000
:
00000000
:
10001000
:
10010000
:
10100000
:
-127steps
11111111
After the adjustment, please adjust machine
parameter 013 and 014.
Usage/Comments
Switch
76543210
127 steps 01111111
:
00100000
:
00010000
:
00001000
:
00000000
:
10000010
:
10001000
:
10010000
:
10100000
:
-127steps
11111111
Settings
+10.76 mm
+2.71 mm
+1.36 mm
+0.68mm
0 mm
-0.68 mm
-1.36 mm
-2.71 mm
-10.76 mm
Settings
+10.76 mm
+2.71 mm
+1.36 mm
+0.68mm
0 mm
-0.17 mm
-0.68 mm
-1.36 mm
-2.71 mm
-10.76 mm