Auto Update
To update the ROM automatically, create a "Boot" folder to the root directory of USB memory, and save the
data there under folders with names under the following rules:
USB flash memory
Machine
Network
PCL
• "xxxxxx" indicates the ROM version. For example : A0A0A0
• "2550" indicates machine name. When you use MFX-2570, replace it to "2570".
• Save a text file with the latest version name and the firmware under the folder with the firmware type name.
• The text file should have a name with the firmware type followed by country code :USA, then an "_"(under-
score) and "Ver".
An example for machine ROM text file: 2550USA_Ver.txt
• The firmware should have a name with the firmware type followed by an "_"(underscore), then the country
code :USA, an "_"(underscore), and the ROM version. Machine ROM should also have the string "update"
following an "_"(underscore).
An example for machine firmware : 2550_USA_A0A0A0_update.bin
• Following are the firmware types and their names:
Firmware type
Machine ROM
Network (OfficeBridge)
PCL
NOTE
Save only one firmware in each folder. Auto Update is not available when two or more firmware are
stored.
1 Turn off the machine.
2 Connect the USB memory in which the firmware is stored.
3 Turn the machine on to start update.
4 When the display shows "Firmware Updating OK", turn the machine OFF and ON.
5 Press <My MFP> and check the ROM version to see the update has succeeded.
Boot
2550USA
OB750
OP700EN
Name
2550 or 2570
OB750
OP700
3-145
2550USA_Ver.txt
2550_USA_xxxxxx_update.bin
OB750_Ver.txt
OB750_xxxxxx.zip
FWUD.bin
OP700EN_Ver.txt
OP700_EN_xxxxxx.bin

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-2570

Table of Contents