Memory switch 07x : Operation
Memory switch 071 :
Initial
bit
Setting
7
0
Factory use only
6
0
Factory use only
Print TCR with the original
5
1
page during memory trans-
mission when the result is
NG
0 : No
1 : Yes
4
0
Factory use only
Print TCR with the original
3
1
page during memory trans-
mission when the result is
OK
0 : No
1 : Yes
2
0
Print T.30 monitor at com-
munication error
0 : No
1 : Yes
1
0
Print T.30 monitor
0
0
Display modem speed
0 : No
1 : Yes
Memory switch 071 — Print TCR with the original page
Switch 3
Switch 5
When Memory transmission was OK, ...
When Memory transmission was NG, ...
When all broadcast transmissions were OK, ...
When some broadcast transmissions were NG, ...
Memory switch 072 :
Initial
bit
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
1
Erase polled document
0 : No
1 : Yes
0
0
Factory use only
Memory switch 073 ~ 075 : Factory use only
Adjust
For easy identification, the first page of a document stored for
memory transmission will print along a TCR when the trans-
mission result is NG.
For easy identification, the first page of a document stored for
memory transmission will print along a TCR when the trans-
mission result is OK.
Set this switch to "1" to print out T.30 monitor automatically at
communication error.
Set this switch to "1" to print out T.30 monitor by each commu-
nication.
The transmit/receive speed is displayed in the LCD.
Adjust
Determines if a document stored for polling is erased after
being polled.
Usage / Comments
0
0
1
0
No
No
Yes
No
Yes
No
No
No
Yes
No
Yes
No
Usage / Comments
3-50
1
1
Yes
Yes
Yes
Yes