3.42.4 Firmware Update Via Network
To update the machine via network, set the items.
1. Open the network service screen. (See page 3-152.)
2. Click [Firmware Update via Network Server].
3. Enter the necessary information.
4. Click [Update] to start update.
5. When updating is finished, the machine reboots from itself.
6. Check the ROM version to see the update has succeeded. The ROM version is displayed at "Machine
Status" on the OfficeBridge.

3.42.5 Firmware Update

NOTE
This updating procedure required enough free space on CF memory card. If there is no free space on CF
memory card, this way of update is unavailable.
1. Open the network service screen. (See page 3-152.)
2. Click [Firmware Update].
3. Click [Browse] to browse the location where the firmware file is located.
eg.
Machine: 2570_USA_A0A0A0_update.bin
Network: OB750_A0A0A0.zip
PCL:
OP700_EN_A0A0A0.bin
4. Click [Update].
5. When updating is finished, the machine reboots from itself.
6.Check the ROM version to see the update has succeeded. The ROM version is displayed at "Machine
Status" on the OfficeBridge.
3-158