PCB RS

1. Open the DADF cover TX. (See DADF FRAME SCANNER)
2. Remove the DADF frame scanner. (See DADF FRAME SCANNER)
3. Remove the Shaft press exit [1] and Roller press A [2].
4. Remove the two screws [3].
5. Remove the Cover lower scanner [5] while releasing the two hooks [4].
6. Remove one screw [6], then remove the Plate shield DADF B [7].
7. Disconnect the connector [8] and remove one screw [9], then remove the PCB RS [10].
[ 6 ]
[ 7 ]
CAUTION
When removing the Cover lower scanner, be careful not to break the Glass contact.
Important
When assembling the Shaft press exit, make sure the side with the notch goes on the front side.
[ 9 ]
[ 8 ]
[ 10 ]
5-31
[ 5 ]
[ 3 ]
[ 4 ]
[ 3 ]
[ 4 ]
[ 2 ]
[ 1 ]
[ 2 ]

Advertisement