Muratec MFX-2550 Field Engineering Manual page 77

Hide thumbs Also See for MFX-2550:
Table of Contents

Advertisement

Machine Parameter 280
Initial
Switch
Setting
7
0
Current adjustment
6
0
Half-letter size
5
0
Plain paper
4
0
3
0
2
0
1
0
The plus setting increases
0
0
the current and the minus
setting decreases it.
Each setting changes by
0.11 mA.
Machine Parameter 281
Initial
Switch
Setting
7
0
Current adjustment
6
0
Envelops
5
0
4
0
3
0
2
0
The plus setting increases
1
0
the current and the minus
0
0
setting decreases it.
Each setting changes by
0.11 mA.
Adjust
When transfer problems occur, adjust this param-
eter.
Switch
31 steps
8 steps
-1 steps
-2 steps
-8 steps
-31 steps
When Switch 7 is "1", it means " - ". For example,
"10000001" means "-0.11 mA".
Adjust
When transfer problems occur, adjust this
parameter.
Switch
31 steps
8 steps
-1 steps
-2 steps
-8 steps
-31 steps
When Switch 7 is "1", it means " - ". For example,
"10000001" means "-0.11 mA".
3-25
Usage/Comments
76543210
Settings
+3.41 mA
00011111
:
+0.88 mA
00001000
:
00000000
-0.11 mA
10000001
-0.22 mA
10000010
:
-0.88 mA
10001000
:
-3.41 mA
10011111
NOTE
• Adjusting them too many steps affect the print
quality. Just try to decrease one or two steps
at first.
• DO NOT adjust the steps larger than 31 or
smaller than -31.
Usage/Comments
76543210
Settings
+3.41 mA
00011111
:
+0.88 mA
00001000
:
00000000
-0.11 mA
10000001
-0.22 mA
10000010
:
-0.88 mA
10001000
:
-3.41 mA
10011111
NOTE
• Adjusting them too many steps affect the print
quality. Just try to decrease one or two steps
at first.
• DO NOT adjust the steps larger than 31 or
smaller than -31.
ur, adjust this param-
r, adjust this param-
this param-
0 mA  Initial setting
0 mA  Initial setting