Muratec MFX-2550 Field Engineering Manual page 119

Hide thumbs Also See for MFX-2550:
Table of Contents

Advertisement

Unique Switch 02x : Reception
Unique Switch 020 :
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
1
Transmit CED signal
0: No
1: Yes
3
1
Pseudo-ring start time
(seconds)
Switch 3: 0
2
0
Switch 2: 0
1
1
Printout the pages completed
to receive during receiving
into memory
0: No
1: Yes
0
1
Factory use only
Unique Switch 021 :
Initial
Switch
Setting
7
0
Factory use only
6
1
Factory use only
5
1
Factory use only
4
0
Factory use only
3
1
TCF check time
(in 100 ms units)
2
0
1
0
0
0
Adjust
Determines if sending CED signal.
Sets the time the pseudo-ring begins after
answering an incoming call.
5
6
8
10
(Fax/Tel Ready or Tel/Fax Ready mode only.)
0
1
1
1
0
1
Determines if whether to printout the page which
data is completed to receive during receiving it into
fax's memory.
Adjust
If the TCF time is such that poor image quality is the
result, lengthen the TCF check time.
3-67
Usage/Comments
Usage/Comments
Switch 3 2 1 0
Time
0 0 0 0
0 ms
0 0 0 1
100 ms
0 0 1 0
200 ms
0 0 1 1
300 ms
0 1 0 0
400 ms
0 1 0 1
500 ms
0 1 1 0
600 ms
0 1 1 1
700 ms
800 ms  Initial setting
1 0 0 0
1 0 0 1
900 ms
1 0 1 0
1000 ms
1 0 1 1
1100 ms
1 1 0 0
1200 ms
1 1 0 1
1300 ms
1 1 1 0
1400 ms
1 1 1 1
1500 ms

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-2570

Table of Contents