Muratec MFX-2550 Field Engineering Manual page 83

Hide thumbs Also See for MFX-2550:
Table of Contents

Advertisement

Memory switch 00x : Dialer
Memory switch 000 :
Initial
bit
Setting
7
0
Factory use only
6
0
Factory use only
5
0
CED detection condition
4
0
3
0
DIS detect time after dialing
0 : 55 sec
1 : 70 sec
2
1
CED detection
0 : No
1 : Yes
1
0
Factory use only
0
0
Phone line type for the first
phone line
0 : PSTN
1 : PBX
Adjust
Sets whether the detection should be strict not.
Switch 5
Sets the DIS signal is detected after dialing a number.
Can be use to ignore CED detection if noise on the telephone
line is mistaken as a 2100 Hz CED signal.
When set to PSTN, the machine checks for dial tone and
acts according to the setting of memory switch 000, bit "1" .
When set to PBX, the machine always dials a given number
of seconds after going off-hook. Memory switch 001 sets the
number of seconds.
Usage / Comments
Normal 
350 ms 500 ms 700 ms 1000 ms
0
0
4
0
1
3-31
 Strict
1
1
0
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-2570

Table of Contents