Memory switch 01x : Transmission
Memory switch 017 :
Initial
bit
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
Time between ANSam out-
3
0
2
0
put and CM output
1
0
0
0
Check only manually en-
tered fax numbers in ID
check transmission
0 : No
1 : Yes
Memory switch 018 ~ 019 : Factory use only
Adjust
When using optical communication line, wait to make sure that
the terminal adopter has turned the echo-canceler off.
Waiting too long may fail the receiver to catch the CM and go
to V 17 procedures.
This setting is needed only for optical communication line.
bit
When set at "1" , the ID check transmission will check only the
manually entered fax numbers and not check the number en-
tered using the address book.
Usage / Comments
321
111
1750 msec
110
1500 msec
101
1250 msec
100
1000 msec
011
750 msec
010
500 msec
001
250 msec
000
Refers the time set on the modem