4.12.5 Blurred background
Symptom: Copies show a gray or dark background.
Poor development
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
4.12.6 Uneven print density
Symptom: Image graduates from dark to light across page.
Poor development
A
B
CDE
A
B
CDE
B
CDE
A
B
CDE
A
B
CDE
A
Defective Drum
Poor image transfer
• Replace the High Voltage Unit.
• Replace the Main Control PCB.
• Replace the Toner Cartridge.
• Replace the Drum Cartridge.
• The drum cartridge or toner cartridge may be not installed correctly. Install
each cartridge correctly.
• Replace the Toner cartridge
• Replace the High Voltage Unit.
• Clean the LED print head.
• If the drum surface for moisture condensation found, leave drum in unit with
power on to dry.
• Replace the Drum Cartridge.
• Replace the Image Transfer Unit.
• Replace the High Voltage Unit.
• Replace the Main Control PCB.
4-22