Clearing The Memory Switches - Muratec MFX-2550 Field Engineering Manual

Hide thumbs Also See for MFX-2550:
Table of Contents

Advertisement

3.3.2 Clearing the Memory Switches

Resets the memory switches to factory defaults.
1. Press <Setting>, <*>, <0>, <1>.
2. Press [Mem Switch Clear].
3. Press [Yes]. The memory switches will reset to factory defaults.
Adjustable items :
• CED detection condition
000
• DIS detect time after dialing
• CED detection
• Phone line type for the first phone line
• DIS detection condition
001
• PBX mode dial pause
• Redial in D.0.7 error
002
•DTMF attenuation
004
• Ring signal detect time
005
• Number of CI signal detection in Fax / Tel Ready mode
• Dual ring detection
• Long ring detection
• Frequency of the CI signal
• Busy tone detection
010
• Fallback pattern
• Overseas mode
• V. 29 Echo Protect tone
• Maximum transmit speed
• Time between reception of CFR and transmission of data
011
• Interval between DCS and TCF
• Output attenuation
• TTI clock type
012
• TTI calendor type
• TTI transmit
• ECM response time
• ECM error retransmit time
• Interval between DIS and DCS
• ANSam detection
013
• V. 34 transmission
• CSI / TSI / CIG transmit
• ECM mode
• Retransmit automatically when receiving RTN / PIN signals
• Program individual autodialer attributes
015
• Sending RTC signal when transmission is canceled
• Cancel redial if T.4.1 or T.4.4 error occurs
• Action after EOR signal
• Additional data on TTI transmit
016
• Subscriber ID transmit
• TTI (name) transmit
• Time between ANSam output and CM output
017
• Check only manually entered fax numbers in ID check transmission
• Data error rate
020
• Pause one second after sending CED
• Time between ANSam output and DIS output
• Receive speed
• DIS "inch" declaration
021
• T1 timer
• Print image data when post message is not received after receiving
RTC signal
• DIS / DTC Extend field Transmit
• G3 echo receive
3-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-2570

Table of Contents