ROLLER PICKUP MP/PAD PRESSURE MP

1. Remove the Cover connect. (See COVER CONNECT)
2. Remove the Cover option. (See COVER OPTION)
3. Remove the Cover shield. (See COVER SHIELD)
4. Remove the Cover back. (See COVER BACK)
5. Remove the Clutch [1]. (See CLUTCH)
6. Remove the Cover jam access. (See COVER JAM ACCESS)
7. Remove two E-rings [2].
8. Lift up the Guide paper MPDUP [3] and push down the MP pressure [4].
9. Remove the ROLLER PICKUP MP [5] by sliding it to the left.
10. Remove the PAD PRESSURE MP [6].
Important
When attaching the Pad pressure MP, align it with the notch in the main unit.
[ 3 ]
[ 4 ]
[ 2 ]
[ 5 ]
[ 6 ]
5-101
[ 1 ]