Muratec MFX-2550 Field Engineering Manual page 65

Hide thumbs Also See for MFX-2550:
Table of Contents

Advertisement

Machine Parameter 030
Switch
Initial
Setting
7
0
For MFX-2570
Back side of document
6
0
5
0
DADF scanner registration
4
0
adjustment (Horizontal)
3
0
2
1
Adjusts the start point to
1
0
scan the document.
0
0
The plus setting increases
the left margin and the minus
setting decreases it.
1 step = 5 / 600 dpi
Machine Parameter 031
Initial
Switch
Setting
7
0
For MFX-2570
Back side of document
6
0
5
0
Adjustment of the scanning
4
0
stretching and squeezing for
3
0
DADF.
2
0
(Horizontal)
1
0
0
0
The plus setting stretches the
image data and the
minus setting squeezes it.
Each setting changes by
0.01%
Machine Parameter 032— Factory use only
Adjust
(0.2117 mm)
Adjust
3-13
Usage/Comments
bit
76543210
25 steps
00011001
:
00010000
:
00001000
:
00000000
:
10001000
:
10010000
:
-25 steps
10011001
Usage/Comments
bit
76543210
01111111
:
00010000
:
00000100
:
00000000
:
10000100
:
10010000
:
11111111
+5.29 mm
+3.39 mm
+1.69 mm
0 mm
-1.69 mm
-3.39 mm
-5.29 mm
+1.27%
+0.16%
+0.04%
0%
-0.04%
-0.16%
-1.27%

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx-2570

Table of Contents