SENSOR PDS/DPS/SHIFT (MFX-2570 only)

1. Remove the Cover connect. (See COVER CONNECT)
2. Remove the Cover option. (See COVER OPTION)
3. Remove the Cover shield. (See COVER SHIELD)
4. Remove the Cover back. (See COVER BACK)
5. Remove the Chassis FBS. (See PCB CONNECT LPH)
6. Remove the Cover left. (See PCB NCU)
7. Remove the Frame upper. (See ASSY INTERLOCK)
8. Remove the Roller exit. (See SHAFT ROLLER PRESS/ROLLER EXIT)
9. Remove the two screws [1], then remove the Guide fuser [2].
10. Remove the connector of Sensor PDS [3]/DPS [4], and remove the harness from its path.
11. Release the hooks from the reverse side and remove the SENSOR PDS [3]/DPS [4].
12. Disconnect the connectors, release the hooks from the reverse side and remove the SENSOR SHIFT [5].
[ 1 ]
[ 2 ]
[ 1 ]
[ 3 ]
[ 4 ]
[ 5 ]
5-107